AC 20A / 200A
|
Á¦Á¶»ç |
: YOKOGAWA |
Á¦Ç°¸í |
: CLAMP METERS |
Á¦Ç°¹øÈ£ |
: CL120 |
Á¦Ç°ºÐ·ù |
: Ŭ·¥ÇÁ¹ÌÅÍ |
|
|
|
|
|
|
|
|
|
 |
|
¡Ü LIGHT WEIGHT & COMPACT DESIGN
¡Ü MEAN VALUE DISPLAY
¡Ü DATA HOLD FUNCTION
¡Ü APPROVED F COMFMITY TO SAFETY STARDS EN61010-1,EN61010-2-032 (CAT. III 300 V)
|
|
|
 |
|
Specifications
Display (LCD, Digital Counts) |
1999 |
AC Current Accuracy (20A Reference) |
2.07 (50~1kHz) |
AC Current Accuracy (200A Reference) |
2.05(50/60Hz) 3.010(40~1kHz) |
Method of detection |
Mean Value |
Response Time |
Approx. 2 seconds |
Range Switching |
Manual-range |
Data hold |
On all range |
Operating temperature and humidity |
0-40°C, 85% RH or less (no condensation) |
Influence of external magnetic field |
0.8A or less at 400A/m |
Influence of conductor position |
± 2% or less |
Safety Standard |
Conforms EN 61010-1, EN61010-2-032 |
Circuit voltage |
300Vrms or less |
Withstanding voltage |
3.7kV AC for one minute |
Power Supply |
LR-44x2(3V) or SR-44x2 |
Battery Life1 |
100 hours |
Consumed current |
Approx. 1mA |
Auto power-off |
Approx. 10 minutes |
Diameter of measurable conductor |
24mm at maximum |
Dimensions |
Approx. 59(W)x210(H)x40(D)mm |
Weight (Approx.) |
400g |
Accessories |
Clamp Adapter (Model 99025), Carrying Case (Model 93033), User''s manual (IM CL120), Batteries |
Order Notes |
Each item selected MUST be ordered as a separate line item. |
Product Notes |
All Clamp-on Meters include Test Leads (where applicable) and a carrying case. |
 
Selection Guide
AC Current Range |
20/200A |
AC Current Resolution |
0.01A |
AC Current Frequency characteristics |
40~1kHz |
AC Current Method of detection |
Mean Value |
AC Voltage Measurement |
- |
DC Voltage Measurement |
- |
Continuity Check Measurement |
- |
Frequency Measurement |
- |
Temperature Measurement |
- |
Recorder output Function |
- |
Waveform monitor output Function |
- |
Data hold Function |
O |
Auto hold Function |
- |
Peak Hold Function |
- |
Maximum value memory Function |
- |
Mean value display Function |
- |
Filter Function |
- |
Range Hold Function |
O |
Auto ZERO Adjust Function |
- |
Auto power-off Function |
O |
|
|
|
|
|
|
|
|
|