AC/DC 40/300A
|
Á¦Á¶»ç |
: YOKOGAWA |
Á¦Ç°¸í |
: CLAMP METERS |
Á¦Ç°¹øÈ£ |
: CL220 |
Á¦Ç°ºÐ·ù |
: Ŭ·¥ÇÁ¹ÌÅÍ |
|
|
|
|
|
|
|
|
|
 |
|
¡Ü LIGHT WEIGHT & COMPACT DESIGN
¡Ü MEAN VALUE DISPLAY
¡Ü SLEEP FUNCTION
¡Ü APPROVED FOR COMFORMITY TO SAFETY STANDARDS EN61010-1, EN61010-2-032 (CAT. III 300 V)
|
|
|
 |
|
Specifications
Description |
AC/DC Mini Clamp-on |
Method of detection |
Mean Value |
Display |
LCD (Digital display: 3999 counts) |
DC Current Range |
40/300A |
DC Current Resolution |
0.01A |
Response Time |
Approx. 2 second |
Range Switching |
Auto-range |
Data hold |
On all range |
Operating temperature and humidity |
0 - 40°C, 90% RH or less (no condensation) |
Influence of external magnetic field |
1A or less at 400 A/m |
Influence of conductor position |
±(2% rdg 5dgt) or less |
Safety Standard |
Conforms EN61010-1, EN61010-2-031, EN61010-2-032 |
Circuit voltage |
300 Vrms or less |
Withstanding voltage |
3.7 kV AC for one minute |
Power Supply |
LR-44 x 2 (3V) SR-44 x 2 |
Battery Life |
Approx. 11 hours (continuous) |
Consumed current |
Approx. 9 mA |
Sleep Function |
Automatically powered down in about 5 minutes after the last switch operation |
Diameter of measurable conductor |
24 mm at maximum |
Dimensions |
Approx. 59 (W) x 147 (H) x 25 (D) mm |
Weight |
Approx. 100 g |
Accessories |
Batteries, carrying case (93033) User''s manual (IM CL235) |
 
Selection Guide
AC Current Range |
40/300A |
AC Current Resolution |
0.01A |
AC Current Frequency characteristics |
20~1kHz |
AC Current Method of detection |
Mean Value |
AC Voltage Measurement |
- |
DC Voltage Measurement |
- |
Continuity Check Measurement |
- |
Frequency Measurement |
- |
Temperature Measurement |
- |
Recorder output Function |
- |
Waveform monitor output Function |
- |
Data hold Function |
O |
Auto hold Function |
- |
Peak Hold Function |
- |
Maximum value memory Function |
- |
Mean value display Function |
- |
Filter Function |
- |
Range Hold Function |
- |
Auto ZERO Adjust Function |
O |
Auto power-off Function |
&Delta |
 
Additional Specification
At 23°C±5°C, 75%RH or less Accuracy: ±( % rdg dgt) = ±(% readout value of least significant digit)
Parameter | Reference | Accuracy |
DC current |
40A |
1.04 |
300A(±20¢¦±200A) |
1.54 |
300A(±200¢¦±300A) |
3.0 |
AC current |
40A |
1.04 (50/60Hz) |
2.54 (20¢¦1kHz) |
300A(20¢¦200A) |
1.54 (50/60Hz) |
2.54 (20¢¦1kHz) |
300A(200¢¦300A) |
3.5 (50/60Hz) |
4.0 (20¢¦1kHz) |
|
|
|
|
|
|
|
|
|