AC/DC 400/2000A, AC 40/400/750, DC40/400/1000V(RMS), (DC OUTPUT±â´É)
|
Á¦Á¶»ç |
: YOKOGAWA |
Á¦Ç°¸í |
: CLAMP METERS |
Á¦Ç°¹øÈ£ |
: CL255 |
Á¦Ç°ºÐ·ù |
: Ŭ·¥ÇÁ¹ÌÅÍ |
|
|
|
|
|
|
|
|
|
 |
|
¡Ü TRUE RMS DISPLAY
¡Ü SLEEP FUNCTION
¡Ü DATA HOLD FUNCTION
¡Ü APPROVED FOR COMFORMITY TO SAFETY STANDARDS EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V, CAT. II 1000 V) /HZ
|
|
|
 |
|
Specifications
Description |
True RMS ACA, DCA, ACV, DCV |
Method of detection |
True RMS |
Display |
LCD (Digital display: 3999 counts) |
DC Current Range |
400/2000A |
DC Current Resolution |
0.1A |
Response Time |
Approx. 1 second (on DC current/voltage range) Approx. 2 seconds (AC current/voltage range, resistance range) |
Range Switching |
Auto-range |
Operating temperature and humidity |
0 - 40°C, 85% RH or less (no condensation) |
Influence of external magnetic field |
4A or less at 400 A/m |
Influence of conductor position |
±(1.5% rdg 3 dgt) or less |
Safety Standard |
Conforms EN61010-1, EN61010-2-031, EN61010-2-032 |
Circuit voltage |
1000 Vrms or less |
Withstanding voltage |
5.55 kV AC for one minute |
Power Supply |
6F22 (006P) 9V x 1 6LR61 x 1 |
Battery Life |
Approx. 15 hours (continuous) |
Consumed current |
Approx. 15 mA |
Sleep Function |
Automatically powered down in about 10 minutes after the last switch operation |
Diameter of measurable conductor |
55 mm at maximum |
Dimensions |
Approx. 105 (W) x 250 (H) x 49 (D) mm |
Weight |
Approx. 540 g |
Accessories |
Batteries, carrying case (93034) Output plug (98012) Test Lead (98011) User''s manual (IM CL250) |
Peak Hold |
On current / Voltage range |
 
Selection Guide
AC Current Range |
400/2000A |
AC Current Resolution |
0.1A |
AC Current Frequency characteristics |
30~1kHz |
AC Current Method of detection |
True RMS |
AC Voltage Measurement |
O |
DC Voltage Measurement |
O |
Continuity Check Measurement |
O |
Frequency Measurement |
O |
Temperature Measurement |
- |
Recorder output Function |
O |
Waveform monitor output Function |
- |
Data hold Function |
O |
Auto hold Function |
- |
Peak Hold Function |
O |
Maximum value memory Function |
- |
Mean value display Function |
O |
Filter Function |
- |
Range Hold Function |
- |
Auto ZERO Adjust Function |
O |
Auto power-off Function |
&Delta |
 
Additional Specification
At 23°C±5°C£¬75%RH or less Accuracy: ±( % rdg dgt) = ±(% readout value of least significant digit)
Parameter | Reference | Accuracy |
DC current |
400/2000A |
1.52 |
AC current |
400A/2000A (150¢¦1700A) |
1.53 (50/60Hz) |
3.04 (30¢¦1kHz) |
2000A (1701¢¦2000A) |
1.02 |
DC voltage |
40/400/1000V |
3.53 (50/60Hz) |
AC voltage |
40/400/750V |
1.02 |
1.53 (50/60Hz) |
2.04 (30¢¦1kHz) |
Crest factor |
  |
?3 |
Resistance |
400/4000&Omega |
1.52 , Beeps at below 20&Omega (continuity check) |
Frequency |
10¢¦3999Hz |
1.55 |
DC output |
DC400A (0¢¦400mV) |
±1.5% rdg ±3mV |
DC2000A (15¢¦200mV) |
±1.5% rdg ±3mV |
AC400A (0¢¦400mV) /AC2000A (15¢¦170mV/150¢¦1700A) |
±1.5% rdg ±3mV (50/60Hz) |
±3.0% rdg ±3mV (40¢¦1kHz) |
AC2000A (170.1¢¦200mV/1701¢¦2000A) |
±3.5% rdg ±3mV (50/60Hz) |
|
|
|
|
|
|
|
|
|