  Ä¶¸®ºê·¹ÀÌÅÍ
  Å¬·¥ÇÁ¹ÌÅÍ
  AC Calibrator
  Power Supply

- - CL320

AC 20M/200M/200A

Á¦Á¶»ç : YOKOGAWA

Á¦Ç°¸í : CLAMPE METERS

Á¦Ç°¹øÈ£ : CL320

Á¦Ç°ºÐ·ù : Ŭ·¥ÇÁ¹ÌÅÍ

Á¦Ç°Á¤º¸

  • MEAN VALUE DISPLAY
    AUTO POWER-OFF
    MANUAL RANGE SWITCHING
    APPROVED FOR COMFORMITY TO SAFETY STANDARDS EN61010-1,EN61010-2-032(CAT. III 300 V)

Á¦Ç°»ó¼¼Á¤º¸


Description Leakage Current Mini Clamp-on
Method of detection Mean Value
Display LCD (Digital display: 1999 counts)
Response Time Approx. 2 seconds
Range Switching Manual-range
Data hold On all range
Operating temperature and humidity 0 - 40°C, 85% RH or less (no condensation)
Influence of external magnetic field 10 mA or less in proximity to a 14.4 mm-dia conductor carrying 100A
Influence of conductor position Within 5 dgt for 0 to 50A, or 2% for 50 to 200A (10 mm-dia conductor at inside the jaw)
Influence of Residual Current 10 mA or less in proximity to a 10 mm-dia conductor carrying 50A
Safety Standard Conforms EN61010-1, EN61010-2-032
Circuit voltage 300 Vrms or less
Withstanding voltage 3.7 kV AC for one minute
Power Supply LR-44 x 2(3V)
SR-44 x 2
Battery Life Approx. 15 hours (continuous)
Consumed current Approx. 5 mA
Auto power-off Approx. 10 minutes
Diameter of measurable conductor 24 mm at maximum
Dimensions Approx. 60 (W) x 149 (H) x 26 (D) mm
Weight Approx. 120 g
Accessories Batteries, carrying case (93033)
User''s manual (IM CL320)

 

DC Current Range -
DC Current Resolution -
AC Current Range 20/200mA,200A
AC Current Resolution 0.01mA
AC Current Frequency characteristics 40~400Hz
AC Current Method of detection Mean Value
AC Voltage Measurement -
DC Voltage Measurement -
Continuity Check Measurement -
Frequency Measurement -
Temperature Measurement -
Recorder output Function -
Waveform monitor output Function -
Data hold Function O
Auto hold Function -
Peak Hold Function -
Maximum value memory Function -
Mean value display Function -
Filter Function O
Range Hold Function O
Auto ZERO Adjust Function -
Auto power-off Function O

 

At 23°C±5°C£¬75%RH or less
Accuracy: ±( % rdg dgt) = ±(% readout value of least significant digit)

Parameter Reference Accuracy
WIDE(40¢¦400Hz) 50/60Hz
AC current 20mA/200mA 2.04 (50/60Hz) 3.05 (50/60Hz)
200A(0¢¦100A) 5.06 (40¢¦400Hz)
200A(100.1¢¦200A) 5.04 (50/60Hz) 5.05 (50/60Hz)