  AC Calibrator
  Power Supply

- - CL360

AC 200M/2/20/200/1000A, (AC, DC OUTPUT ±â´É)

Á¦Á¶»ç : YOKOGAWA

Á¦Ç°¸í : CLAMP METERS

Á¦Ç°¹øÈ£ : CL360

Á¦Ç°ºÐ·ù : Ŭ·¥ÇÁ¹ÌÅÍ

Á¦Ç°Á¤º¸

  • ¡Ü APPROVED FOR CONFORMITY TO SAFETY STANDARDS EN 61010-1, EN 61010-2-032 (CAT III 300 V, CAT II 600 V)




Á¦Ç°»ó¼¼Á¤º¸


Description Leakage current clamp on AC 1000A
Method of detection Mean Value
Display LCD (Digital display: 1999 counts)
Response Time Approx. 1 second
Range Switching Manual-range
Data hold On all range
Operating temperature and humidity -10 - 50°C , 80% RH or less (no condensation)
Influence of external magnetic field 15 mA or less in proximity to a 10 mm-dia conductor carrying 100A
Influence of conductor position 2% or less
Influence of Residual Current 10 mA or less in proximity to a 10 mm-dia conductor carrying 100A
Safety Standard Conforms EN61010-1, EN61010-2-032
Circuit voltage 300 Vrms or less
Withstanding voltage 3.7 kV AC for one minute
Power Supply 6 LR61 x 1
6F22 (006P) 9V x 1
Battery Life Approx. 60 hours (continuous)
Consumed current Approx. 5 mA
Diameter of measurable conductor 68 mm at maximum
Dimensions Approx. 129 (W) x 248 (H) x 55 (D) mm
Weight Approx. 570 g
Accessories Batteries, carrying case (93031)
User''s manual (IM CL360)
Peak Hold On all range

 

DC Current Range -
DC Current Resolution -
AC Current Range 200mA/2/20/200/1000A
AC Current Resolution 0.1mA
AC Current Frequency characteristics 40~1kHz
AC Current Method of detection Mean Value
AC Voltage Measurement -
DC Voltage Measurement -
Continuity Check Measurement -
Frequency Measurement -
Temperature Measurement -
Recorder output Function O
Waveform monitor output Function O
Data hold Function O
Auto hold Function -
Peak Hold Function O
Maximum value memory Function -
Mean value display Function -
Filter Function O
Range Hold Function O
Auto ZERO Adjust Function -
Auto power-off Function -