- - LR8400
°·ÂÇÑ ¼º´É°ú È޴뼺À» µ¿½Ã¿¡...
Á¦Á¶»ç : HIOKI
Á¦Ç°¸í : ¸Þ¸ð¸® ÇÏÀÌÄÚ´õ
Á¦Ç°¹øÈ£ : LR8400
Á¦Ç°ºÐ·ù : ¸Þ¸ð¸® ÇÏÀÌÄÚ´õ
Á¦Ç°»ó¼¼Á¤º¸
ANALOG INPUT UNIVERSAL UNIT LR8501 ACTUAL FUNCTIONALITY WILL DEPEND ON COMBINATION OF UNITS INSTALLED NOTE: ISOLATED FROM EACH CHANNEL TO CHASSIS |
[NO. OF CHANNELS] 15 ANALOG CHANNELS ISOLATED SCANNING METHOD INPUT (4 TERMINALS: PUSH-BUTTON TYPE) [VOLTAGE] 10 MV TO 100 V, 1-5 V F.S. 10 RANGES, MAX. RESOLUTION: 500 NV NOTE: ISOLATED BETWEEN CHANNELS AND FROM EACH CHANNEL TO CHASSIS [TEMPERATURE: THERMOCOUPLES] -200¡ÆC TO 2000¡ÆC (DEPENDS ON SENSOR), 3 RANGES (K, J, E, T, N, R, S, B, W), MAX. RESOLUTION 0.01¡ÆC NOTE: ISOLATED BETWEEN CHANNELS AND FROM EACH CHANNEL TO CHASSIS [TEMPERATURE: PT 100, JPT 100 SENSOR] -200¡ÆC TO 800¡ÆC, 3 RANGES, MAX. RESOLUTION 0.01¡ÆC NOTE: NOT ISOLATED BETWEEN CHANNELS [RESISTANCE] 10 ¥Ø TO 200 ¥Ø F.S. 4 RANGES, MAX. RESOLUTION 0.5 M¥Ø NOTE: NOT ISOLATED BETWEEN CHANNELS [HUMIDITY] 100 % RH F.S. 5.0 TO 95.0 % RH (WHEN USING Z2000), RESOLUTION 0.1 % RH NOTE: NOT ISOLATED BETWEEN CHANNELS NOR FROM EACH CHANNEL TO CHASSIS [MAX. RATED VOLTAGE BETWEEN ISOLATED INPUT CHANNELS] 300 V DC [MAX. ALLOWABLE INPUT] ¡¾100 V DC [MAX. RATED VOLTAGE FROM ISOLATED TERMINALS TO GROUND] 300 V AC, DC |
ANALOG INPUT VOLTAGE/TEMP UNIT LR8500 ACTUAL FUNCTIONALITY WILL DEPEND ON COMBINATION OF UNITS INSTALLED NOTE: ISOLATED FROM EACH CHANNEL TO CHASSIS |
[NO. OF CHANNELS] 15 ANALOG CHANNELS ISOLATED SCANNING METHOD INPUT (2 TERMINALS: M3 SCREW TYPE) [VOLTAGE] 10 MV TO 100 V, 1-5 V F.S. 10 RANGES, MAX. RESOLUTION: 500 NV NOTE: ISOLATED BETWEEN CHANNELS AND FROM EACH CHANNEL TO CHASSIES [TEMPERATURE: THERMOCOUPLES] -200¡ÆC TO 2000¡ÆC (DEPENDS ON SENSOR), 3 RANGES (K, J, E, T, N, R, S, B, W), MAX. RESOLUTION 0.01¡ÆC NOTE: ISOLATED BETWEEN CHANNELS AND FROM EACH CHANNEL TO CHASSIES [TEMPERATURE: PT 100, JPT 100 SENSOR] [RESISTANCE] NOT AVAILABLE [HUMIDITY] 100 % RH F.S. 5.0 TO 95.0 % RH (WHEN USING Z2000), RESOLUTION 0.1 % RH NOTE: NOT ISOLATED BETWEEN CHANNELS NOR FROM EACH CHANNEL TO CHASSIES [MAX. RATED VOLTAGE BETWEEN ISOLATED INPUT CHANNELS] 250 V DC [MAX. ALLOWABLE INPUT] ¡¾100 V DC [MAX. RATED VOLTAGE FROM ISOLATED TERMINALS TO GROUND] 300 V AC, DC CAUTION: MAX. VOLTAGE FROM TERMINALS TO GROUND WITHOUT DAMAGE |
PULSE, DIGITAL INPUT | [NO. OF CHANNELS] 8 CHANNELS, PULSE / DIGITAL SELECTABLE FOR EACH CHANNEL, M3 SCREW TERMINAL, NOT ISOLATED, COMMON GROUND [PULSE TOTALIZATION] 0 TO 1000 M PULSE, 1 RANGE (NO-VOLTAGE ''''A'''' CONTACT NORMALLY OPEN, OPEN COLLECTOR OR VOLTAGE INPUT), MAX. RESOLUTION 1 PULSE [PULSE REVOLUTIONS] 0 TO 5000 /N (R/S) F.S. 1 RANGE (SAME AS PULSE TOTALIZATION INPUT SIGNAL CONDITION), RESOLUTION 1/N (R/S) NOTE: "N" IS THE NUMBER OF SENSOR OUTPUT PULSES PER REVOLUTION, 1 TO 1000 [DIGITAL INPUT] RECORD LOGICAL "1" OR "0" AT EACH SAMPLING [MAX. RATED VOLTAGE BETWEEN INPUT CHANNELS] NOT ISOLATED [MAX. ALLOWABLE INPUT] 0 TO 50 V |
RECORDING INTERVALS | 10 MS TO 50 MS, 100 MS TO 1 HOUR, 19 SELECTIONS (ALL INPUT CHANNELS ARE SCANNED AT HIGH SPEED DURING EVERY RECORDING INTERVAL) NOTE: LIMITED BY USING CHANNELS AT 10 MS TO 50 MS INTERVAL |
DIGITAL FILTER | SELECT FROM OFF/ 50 HZ/ 60 HZ (THE CUT-OFF FREQUENCY IS AUTOMATICALLY SET) |
DATA STORAGE | INTERNAL MEMORY: 8 M-WORDS, DATA STORAGE MEDIA: CF CARD OR USB MEMORY (ONLY DATA RECORDED TO A GENUINE HIOKI CF CARD IS GUARANTEED) |
LAN INTERFACE | 100BASE-TX, FUNCTIONS: DATA ACQUISITION USING BUNDLED SOFTWARE OR PC COMMANDS, FTP SERVER, FTP CLIENT, HTTP SERVER FUNCTION, OR E-MAIL SYSTEM NOTE: LAN COMMUNICATION SUPPORT PLANNED FROM SOFTWARE VER. 1.20 |
USB INTERFACE | USB 2.0 HIGH-SPEED CAPABLE, SERIES MINI-B RECEPTACLE FUNCTIONS: DATA ACQUISITION USING BUNDLED SOFTWARE OR PC COMMANDS, TRANSFER DATA FROM THE CF CARD TO A PC VIA USB DRIVE MODE NOTE: DATA TRANSFER NOT POSSIBLE FROM USB MEMORY STICKS |
DISPLAY DEVICE | 5.7 INCH TFT COLOR LIQUID CRYSTAL DISPLAY (640 ¡¿ 480 PIXEL) |
OTHER FUNCTIONS | SAVE WAVEFORM DATA IN REAL TIME TO THE CF CARD OR USB MEMORY STICK, NUMERICAL VALUE CALCULATIONS, WAVEFORM CALCULATIONS, AND OTHERS |
AC POWER | USING THE AC ADAPTER 9418-15 (100 TO 240 V AC, 50/60 HZ), 7 VA |
DC POWER | USING THE BATTERY PACK Z1000 (OPTIONAL ACCESSORY), CONTINUOUS USE 5 HR, EXTERNAL POWER: 10 TO 28 V DC (PLEASE CONTACT YOUR HIOKI DISTRIBUTOR FOR CONNECTION CORD) |
DIMENSIONS & MASS | 272 MM (10.71 IN) W ¡¿ 182.4 MM (7.18 IN) H ¡¿ 66.5 MM (2.62 IN) D, 1.8 KG (63.5 OZ), (LR8400-20 MAIN UNIT, EXCLUDING THE BATTERY PACK 370 G/ 13.1 OZ) |
ACCESSORIES | DETAILED OPERATING MANUAL ¡¿1, MEASUREMENT GUIDE ¡¿1, AC ADAPTER 9418-15 ¡¿1, USB CABLE ¡¿1, CD-R (DATA COLLECTION SOFTWARE "LOGGER UTILITY") ¡¿1 |
Á¦Ç°Á¤º¸
¡¤ A4 »çÀÌÁîÀÇ ¸Þ¸ð¸®ÇÏÀÌÄÚ´õ, Ç¥ÁØ 30CH. ÃÖ´ë 60CH »ç¿ë°¡´É(¿É¼Ç ÀåÂø½Ã)
¡¤ ´ë¿ë·® ¸Þ¸ð¸®¿Í µ¥ÀÌŸ º¸È£±â´ÉÀ¸·Î Àå½Ã°£ÀÇ µ¥ÀÌŸÀúÀå¿¡ ¾È¼º¸ÂÃã
¡¤ ¿Âµµ,½Àµµ,¾Ð·ÂµîÀÇ È¯°æº¯È¿¡ ÀÇÇÑ ÇÇÃøÁ¤¹°ÀÇ ÀúÇ×°ª º¯È ±â·Ï°¡´É.
¡¤ 10M SECÀÇ °í¼Ó»ùÇøµ
¡¤ USB ¸Þ¸ð¸® »ç¿ë°¡´É.